Elinchrom BX100 User Manual

elinca sa switzerland www.elinchrom.com  
Operating Manual  
Style BX 100/400  
English  
Multivoltage  
Elinca S.A Style BX 01.09.2008 ENG (73286) Printed in Switzerland  
90/260V  
Introduction  
The Elinchrom Style BX is manufactured by Elinca S.A. CH -1020 Renens/Switzerland  
Dear Photographer,  
Thank you for buying your Style BX compact flash unit.  
All Elinchrom products are manufactured using the most advanced technology. Carefully selected  
components are used to ensure the highest quality and the equipment is submitted to many controls  
both during and after manufacture. We trust that it will give you many years of reliable service.  
All Style BX flash units are manufactured for the studio and location use of professional photogra-  
phers. Only by observance of the information given, can you secure your warranty, prevent possible  
damage and increase the life of this equipment.  
Style 100BX - 400BX  
The quality of light and exceptional performance is the result of long research, application of  
demanding principles, the long experience of ELINCHROM in lighting products for the studio  
and the utilization of the latest technology in this area.  
Totally integrated to the range of the ELINCHROM flashes, the Style 100BX - 400BX units  
maintain the traditional look and function that is ELINCHROM.  
The control provides continuously variable adjustment of the modelling lamp and the flash  
power with precision over 5 f-stop, from full power 1/1 to 1/16 th.  
FCC Class B Compliance Statement  
Note:  
This equipement has been tested and found to comply with the limits for a class B digital device, pursuant to Part  
15 of the FCC Rules and meets all requirements of the Canadian Interference-Causing Equipement Regulations.  
These limits are designed to provide reasonable protection against harmful interference in a residential  
installation. This equipement generates, uses, and can radiate radio frequency energy and, if not installed and  
used in accordance with the instruction manual, may cause harmful interference to radio communications.  
However, there is no guarantee that interference will not occur in a particular installation. If this equipement  
does not cause harmful interferences to radio or television reception, which can be determined by turning the  
equipement off and on, the user is encouraged to correct the interferences by one or more of the following  
measures:  
- Reorient or relocate the receiving antenna.  
- Increase the separation between the equipement and receiver.  
- Connect the equipement into an outlet on a circuit different from that to which the receiver is connected.  
- Consult the dealer or an experienced radio/TV technician for help.  
ELINCA S.A. is not responsible for any radio or television interference caused by unauthorised modifications of  
this equipement or the substitution or attachment of connecting cables and equipement other than those specified  
by ELINCA S.A. The correction of interference caused by such unauthorised modification, substitution or  
attachment will be the responsibility of the user.  
2
Declaration of conformity  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two  
conditions:  
1. This device may not cause harmful interference.  
2. This device must accept any interference received, including interference that may cause  
undesired operation.  
Product name:  
Trade name:  
Professional Studio Flash unit  
ELINCHROM  
Model number(s):  
Style BX 100/400  
Name of responsible party: Elinca S.A  
Av. De Longemalle 11  
1020 Renens / Switzerland  
Phone :  
Fax:  
+41 21 637 26 77  
+41 21 637 26 81  
We, ELINCA S.A., hereby declare that the equipement bearing the trade name and model number  
specified above was tested conforming to the applicable FCC rules, and that all the necessary steps  
have been taken and are in force to assure that the production units of the same equipement will  
continue to comply with the Comissions requirements.  
Disposal and recycling  
This device has been manufactured to the highest possible degree from materials  
which can be recycled or disposed of in a manner that is not enviromentally  
damaging. The device may be taken back after use to be recycled, provided that is  
returned in a condition that is the result of normal use. Any components not reclaimed  
will be disposed of in a environmentally acceptable manner.  
If you have any question on disposal, please contact your local office or your local ELINCHROM  
agent (check our website for a list of all ELINCHROM agents world wide).  
CE marking  
The shipped version of this device complies with the requirements of ECC directives  
89/336/ECC «Electromagnetic compatibility» and 73/23/ECC «Low voltage directive».  
Notational Conventions  
The meaning of the symbols and fonts used in this manual are as follows:  
Pay particular attention to text marked with this symbol.  
Failure to observe this warning endangers your life, destroys the device, or may  
damage other equipement  
!
Supplementary information, remarks, and tips follow this symbol.  
Text which follows this symbol describes activities that must be performed in the  
order shown.  
i
«Quotation marks» indicate names of chapters or terms  
3
Safety notice  
According to safety regulations, we draw your attention to the fact that these  
electronic flash units are not designed for use outdoors, in damp or dusty conditions and should  
not be used after being exposed to sudden temperature changes causing condensation. They must  
always be connected to an earthed (grounded) mains supply.  
On no account should any object be inserted into the ventilation holes.  
The units may retain an internal charge for a considerable time even though disconnected from the  
power supply.  
• Do not use in restricted areas (like hospitals, etc.).  
• Do not use in explosive environnements.  
Flash Tubes and Modelling lamps  
• Flash tubes and modelling lamps in use are very hot!  
• Never touch a flash tube or lamp before the unit cooled down and is disconnected from  
the mains (min 30mn).  
• Do not fire flashes from short distance (less than 1m) directed to a person and avoid looking  
directly into the flashlight!  
• Keep (min 1m) distance to flammable materials.  
• Keep generally distance to operating units.  
Transport  
Transport the flash unit with care and only in its original packaging or another corresponding  
packaging fit to protect it against knocks and jolts.  
Transport only in complete discharged conditions. Wait a minimum 30 minutes after removing  
from mains supply before packaging and transportation.  
• Never drop the flash unit (danger of glass breakage)  
Power cable  
To guarantee safe operation, use the cable supplied.  
• The cable has to be HAR-certified or VDE-certified. the mark HAR or VDE will appear on the outer  
sheat.  
• The cable set must be selected according to the rated current for your flash unit.  
• Do not use a spider box to connect one or more flash units.  
• Flash systems store electrical energy in capacitors by applying high voltage.  
• For your safety, never open or disassemble your flashes.  
• Only an authorised service engineer should open or attempt to repair the units.  
• Internal defect charge capacitors may explode whilst the unit is in use, neve  
switch on a not proper working flash unit.  
!
4
Before you start !  
The units Style BX (Multivoltage) are adapted for operation on 90 - 260V/50 - 60Hz.  
Before connecting for the first time, check to make sure that your Modelling lamp coincides  
with the voltage line. They must always be connected to an earthed ( grounded) mains supply.  
All Style BX units have a bayonet mount and locking ring reflector fitting, for fixing all Elinchrom and  
Prolinca accessories.  
Mount the unit securely to a suitable stand or support.  
Remove the black protective cover (note: first turn the locking ring A as shown, then rotate the  
black cap cover B in the same direction). Fitting a reflector or accessory is the reverse of this action.  
DO NOT operate the unit without first removing the black protective cover.  
Operating instructions  
1.Check that the modelling lamp voltage is correct.  
2.Check that the mains switch (3) is in the OFF ("O" position).  
3.Insert mains cable to the MAINS INLET (1) and connect to a FULLY EARTHED OUTLET  
4.Using the mains SWITCH (3) and switch the unit ON ("I" position).  
5.Connect the synchro cord on the socket (6).  
6.Select the power with the touch pad (11 - 12)  
12  
11  
6
1
3
Handle  
A
Locking ring  
B
Protective  
cover  
(26124)  
Tilthead with locking  
C
umbrella holder  
5
Control Panel  
13 14 15 18  
9
10  
7
8
5
12  
11  
4
2
6
3
16  
1
21 19 17  
20  
Overview of controls  
1. Mains inlet socket  
2. Mains fuse (slow blow)  
12. + Power adjustment in 1/10 f-stops  
13. Modelling lamp switch  
(on/off free or prop)  
14.+ Modelling power control  
15. - Modelling power control  
16. Tilt head clamp  
3. Mains light up on/off switch  
4. Modelling fuse (fast blow)  
5. Open-flash  
6. Synchro-sockets + jack 3.5 mm  
7. Digital power display and charge/discharge  
indicator  
17. Knurled clamp screw  
18. Handle  
8. Acoustic recharging signal (Beep)  
9. Slave cell switch on/off  
10. Photocell receptor  
19. Stand 5/8-inch socket  
20. Umbrella tube (only for EL umbrellas,  
diameter 7 mm)  
11. Power adjustment in 1/10 f-stops, with ADF 21. Supplementary locking for others  
umbrellas  
6
Switch and Fuse  
Mains Supply  
With the MAINS SWITCH (3) switched off ("O" position), firmly push in the plug  
of the original ELINCHROM mains cord into the mains socket (1).  
Mains Switch  
The switch should light up when the compact is switched on ("I" position).  
(Switch off before removing the mains cord).  
Troubleshooting  
If the on/off switch (3) is ON ("I" position) but not illuminated,  
switch off the unit and check the mains fuse (2).  
If failed replace with the correct fuse and switch ON the unit.  
This unit is protected by a thermal circuit breaker to avoid overheating.  
Should this occur, the unit turns off automatically and cannot be fired.  
After a break for cooling, the flash will be ready again for operation.  
See page 11: Troubleshooting  
This equipment is not user serviceable and contains high voltages which are dangerous.  
In the event of failure, please return the unit to an authorized Elinchrom service station.  
Mains Fuse  
Standard type 5 x 20 mm, (use only tempered fuse)  
8 AT (code 19022) for Style 100BX and Style 400BX  
Note: Before exchanging a blown fuse, switch off the unit and remove mains cable. Depress and  
turn the fuse holder anti-clockwise 1/8th, turn and remove it. If the new fuse blows immediately  
upon reconnection, return the unit to an ELINCHROM service centre for a check-up.  
(N.B. Please don't forget to check the correct rating of the fuse !).  
Fuse for modelling light  
Fast type 5 x 20mm, 4 AF  
Switch off the unit and replace the blown fuse with a new one of the correct rating.  
The fastblow fuse will protect the triac of the modelling lamp circuit, the lamp and therefore  
the flash tube.  
Mains socket  
1
Modelling fuse  
4
Mains fuse  
2
(Only tempered)  
3
Mains switch  
7
Modelling Light  
The touch pad (14) controls the modelling lamp on/off and the proportional light.  
Select the power with the touch pad (15). The modelling light output (100%) is achieved when  
the power value is set to maximum.  
Proportional modelling lamp, is set when the position "PROP" is selected (led is illuminated), the  
light output is proportional to the selected flash power.  
For all types of Style BX compact flash units use only 250 W MAX. lamps  
Modelling lamps and fuse for 90/140V  
Unit  
Modelling lamp  
150W Halostar  
150W Halostar  
150W Halogen  
200W Halogen  
Code  
23019  
23019  
23031  
23033  
Socket  
E27  
Fuse  
4AF  
4AF  
4AF  
4AF  
Code  
19035  
19035  
19035  
19035  
Style 100BX  
Style 400BX  
Option:  
E27  
GX 6,35  
GX 6,35  
Option:  
Modelling light for mains voltage 190/260V  
Use 150W/240V halostar, code 23035 or 200W/240V halogen GX 6.35, code 23034  
If the modelling lamp does not illuminate, this may be due to the following:  
1. The filament is broken after long use *(replace lamp and fuse)  
2. The filament is broken after shock *(replace lamp and fuse)  
3. An internal component failure, *(return the unit to customer service)  
* Action required:  
This lamp socket adapter E27 to GX 6.35 (code 23101) allows the use of the halogen lamp  
300W, GX 6.35 (code 23022) for Style 100 and 400 BX units.  
GX 6.35  
E27  
8